Start Up; Use - Atlas Filtri HYDRA Serie Instrucciones De Instalación Y Mantenimiento

Ocultar thumbs Ver también para HYDRA Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Modes for presentation of inlet and outlet directions (arrows) in different filter
housings models
B
IN
IN
OUT

6 - Start Up

- Keep the filter package with label affixed to identify the product.
- Ensure that the sealing is tight and secure.
- As the installation of the filter and the connection of the rubber hose to the drainage
are made, proceed as follows:
- by gradually opening the water supply to the filter, make sure there is no water
leaking;
- gradually fill the filter to the top then release air in the filter as following:
- for HYDRA: by opening the vent-valve on the head of the filter, making sure all air
is released and the filter becomes completely filled with water, then tighten the
vent-valve;
- for HYDRA M: Release air from the filter by opening a tap downstream the filter in
the pipe-line.
- After the installation, run the tap and let the water flow for at least 5 minutes before use.
7 - Use (check the label on the package to identify the product
series and model)
- Refer to Figure C for installation layout.
- HYDRA series of filter housing with plastic threaded connections are certified by
IAPMO RT against NSF/ANSI Standards 42, 61, 372-lead free, CSA B483.1 for the
filtration of drinking water. Do not use for the filtration of drinking water, do not use
for filtration of water that is unsafe or of unknown quality. Systems certified for cyst
reduction may be used on waters that contain filterable cysts.
- Check for the filter model from the label applied on the product package and from
the legend "Sticker Legend" printed on the package.
- Respect the working parameters shown in the label affixed to the filter housing.
- If pressure exceeds the working conditions, protect the product with a pressure
reducer.
- Keep protected from light. Supply cold water only, with pH in the range of drinking
water.
- Use only HYDRA HOT filters for hot water filtration (applicable working temperature
on product's label).
- Protect from excessive cold or heat: do not expose to temperature below 39°F (4°C)
or above 113°F (45°C).
- For temperature above 113°F (45°C) use the HYDRA HOT model which can stand up
to 176°F (80°C).
- Protect from back-flows of water with a non-return valve.
- Protect from hammering with an anti-hammering device.
- Should the filter be unused for 1 week or more remove the cartridge, wipe clean and
store in clean, dry place. Insert the cartridge back into the filter only prior to use.
The values of the maximum working temperature and the maximum
working pressure shown in the label affixed to the filter housing are
intended as maximum working parameters and must not be exceeded. Use
of the filter housing under higher pressure and/or higher temperature
conditions could cause ruptures.
IN
The initial quality of the water will not be optimal unless
the tap runs for at least 5 minutes before use.
OUT
IN
OUT
4