R Ating Date 3- Phase Ac Motor; O Peratin Conditions; W Orking Instructions - SUHNER ROTO TT Documentación Técnica

Ocultar thumbs Ver también para ROTO TT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Insert the shaft coupling completely into the machine
coupling. To do so, turn the shaft so that the squared end
is aligned with the receiver and can be inserted.
Release the machine coupling. The shaft is now secured.
2.1.4 c
onnecting the hanD pieces to the flexiBle shaft
Only SUHNER TURBO TRIM hand pieces
and ring cutters may be used. See the op-
erating instructions for the SUHNER TUR-
BO TRIM hand pieces SH or SHS for mounting and re-
moving the hand pieces and ring cutters.
Very sharp blade!
2.1.5
m
ounting the hanD piece
Open the receiver.
Press the hand piece into the receiver until it engages
Only trained persons may use hand pieces. Op-
eration requires the greatest attention if the opera-
tor and others are not to be injured. Never attach
the hand piece to the suspension attachment on the mo-
tor when the ring cutter is rotating. The motor must first be
switched OFF before the hand piece is inserted in the
suspension attachment. The ring cutter must be aligned
towards the motor. Never leave the hand piece lying on
the work surface or hanging freely from the motor housing
with the flexible shaft.
Very sharp blade!
2.2 r
3-
ating Date
phase
Power at 2'930 min -1
Power at 3'550 min -1
Protection class
Type of protection
Voltage
Idling speeds
Sound pressure level
Weight
2.3 o
peratin conDitions
Temperature range during operation: 0 to +50°C.
Relative air humidity: 90% at +30°C, 65% at +50°C.
3. h
aNDlINg
3.1 w
orKing instructions
Avoid sharp deflections on the flexible shaft while
it is operating. Overly small bend radii cause pre-
mature wear.
If the operating ring cutter stops against a foreign
body in the teeth, the motor and hand piece will
start rotating about their own axis! Immediately
switch OFF the machine! Before prolonged downtimes,
remove the shaft and hand piece and place the straight
shaft in storage.
ac
motor
0.4kW, 230V
0.4kW (0.54hp), 120V
1
IP56
230VAC, 1-Phase, 50Hz
120VAC, 1-Phase, 60Hz
3'000/3'600 min -1
56dB(A)
12kg