Fig. 10
5 MIN
1 MIN
30 SEC
10 SEC
Y
PRESENCE
TIME
According to DIN18650-1, EU12978, the door control system must have a
test function, which checks the presence detector for correct function and
connection at least once per door cycle.
Active high, test pulse: 12-24 VAC/DC
Active low, test pulse: 12-24 VAC/DC
See test sequence (Operating Diagram) on page 54
EC Declaration of Conformity
Carlo Gavazzi Industri A/S, Over Hadstenvej 40, DK-8370 Hadsten, Denmark,
declare that the product Guardian 1 is in conformity with:
Low-Voltage Directive 2006/95/EC
EN60947-1: 2007 Low-voltage switchgear and control gear - General rules
EMC Directive 2004/108/EC
EN61326-1: 2006 Electrical equipment for measurement. Control and labora-
tory use – EMC requirements – Part 1: General Requirements
EN61000-3-1: 2008 Electrical equipment for measurement, control and labo-
ratory use - EMC requirements - Part 3-1: Immunity requirements for safety-
related systems and for equipment intended to perform safety-related func-
tions (functional safety) - General industrial applications
Machinery Directive 2006/42/EC
EN ISO 13849-1: 2008 Safety of machinery - Safety-related parts of control
systems - Part 1: General principles for design
DIN18650-1: 2003 Building hardware. Powered pedestrian doors.
Part 1: Product requirements and test methods
prEN16005: 2009 Powered pedestrian doors - Safety in use of power pedes-
trian doors - Requirements and test methods
Person authorised to compile the technical file:
K. Soerensen, Carlo Gavazzi Industri A/S
EC type examination No. 44 205 09 555114.
Notified body 0044
TÜV NORD CERT GmbH, Langemarckstr. 20, 45141 Essen, Germany
The sensor surface must be cleaned with soft cotton. Light soap water can be
used. No alcohol must be used as the frontglass can be miscoloured.
10
Presence Time Settings
The presence time is used to "hold" the door
open if a person or object is present and not
moving in the presence zon. After the "Presence
time" has expired, the doors will close. If an ob-
ject has not moved within the "Presence time",
the object will be stored as part of the back-
ground. The "Present time" can be set on the
rotary switch for 10 sec, 30 sec, 1 min or 5 min.
See fig. 10
Test Input
0 VAC/DC
0 VAC/DC
Maintenaince
t
t