G
B
J1
DO NOT REMOVE ANY JUMPER! OTHERWISE THE
OPERATOR WILL NOT WORK!
J2
AERIAL
Radio Antenna
LSC
Close limit-switch that cuts off the motor in closing
LSO
Open limit-switch that cuts off the motor in opening
COM
Limit-switch common contact
PED BUTT
Pedestrian opening contact (NO)
J3
L-N
Main power supply 230 Vac 50/60 Hz (120V/60Hz upon
request)
J4
EARTH
Connection of the earth line
J5
RADIO
Built-in radio module (model CRX),
or connector for radio receiver RIB, 24Vdc supply
J6
A+ TEST
24Vdc safety strip self-test power supply
A+
Accessories power supply +24Vdc
A-
Accessories power supply -24Vdc
COM +
Common contact (common line for all the command and
safety inputs) (+)
K BUTT.
Single pulse contact (NO)
PHOT.
Photocells contact (NC)
EDGE
Safety strip contact (NC)
Buzzer contact (24Vdc max 200 mA) (-)
-
J7
Flashing light (max 40W )
U - MOTOR
Motor common connection
V-W -
Motor phase and capacitor connections
MOTOR
J8
PROBE
Temperature sensor cable connection PROBE (Code
ACG4665 optional)
RELAYS AND MOTOR COMMAND
K1 => Flashing light command
K2 => Closing command
K3 => Opening command
Q1 => TRIAC - Motor command in opening and closing
POINT B - SETTINGS
DIP 1
MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2
PROGRAMMING (See Point D)
DIP 2-1 PROGRAMMING OF THE PEDESTRIAN OPENING (See Point D)
DIP 1-2 STORAGE/DELETION OF RADIO CODES FOR COMPLETE OPENING (DIP 1 ON
followed by DIP 2 ON) (POINT F) ONLY FOR CRX MODELS
DIP 1-3 STORAGE/DELETION OF RADIO CODES FOR PEDESTRIAN OPENING (DIP 1
ON followed by DIP 3 ON) (POINT G) ONLY FOR CRX MODELS
OPERATING MODE SETTINGS
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Photocells active only in closing
OFF - Photocells always active
DIP 5
ON - blinker pre-flashing
OFF - blinker normal-flashing
DIP 6
ON - STEP BY STEP
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
OFF - AUTOMATIC
R1
R2
J1
R1
TRIMMER
Electronic regulator for low speed on approach
LOW SPEED
R2
TRIMMER
Electronic torque regulator
TORQUE
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
DIP 7
ON - electronic brake ENABLED
OFF - electronic brake DISABLED
FOR FAST VERSION code BA03221 - BA03177:
DIP 7
Electronic brake "weak version" (OFF)
Electronic brake "strong version" (ON)
DIP 8
ON - low speed in approaching DISABLED
OFF - low speed in approaching ENABLED
DIP 9
ON - gradual start ENABLED
OFF - gradual start DISABLED
DIP 10
ON - safety strip self-test ENABLED
OFF - safety strip self-test DISABLED
DIP 11
to select type of motor (see chart 1)
DIP 12
to select type of motor (see chart 1)
DIP 11
DIP 12
MOTOR TYPE
OFF
OFF
K800 - K1400 - SUPER 2200
ON
OFF
K5 - K500
OFF
ON
K2200
ON
ON
FREE FOR FUTURE APPLICATIONS
20
J3
J4
J2
J5
CHART 1
J7
J6
J8