CHART 1 FOR FAST VERSION
DIP 11
DIP 12
MOTOR TYPE
OFF
OFF
SUPER 2200 FAST
ON
OFF
K500 FAST
ON
ON
K800 FAST
OFF
ON
K500 FAST OR FREE FOR FUTURE APPLICATIONS
S1 => PROG. Programming button
TORQUE => R1 Electronic regulator for motor torque
Adjustment of motor torque is carried out using the TORQUE Trimmer which varies the output
voltage to the head/s of the motor/s (turn clockwise to increase torque).
This torque control is activated after 2 seconds form any manoeuvre begging, whereas the
motor is turned on at full power to guarantee the starting at the manoeuvre begging.
PAY ATTENTION: IF THE TORQUE TRIMMER SETTING IS CHANGED, IT IS PREFERABLE
TO REPEAT THE TIME PROGRAMMING.
LOW SPEED => R1 Electronic regulator for low speed on approach
Adjustment of low speed is carried out using the LOW SPEED Trimmer which varies the
output voltage to the head/s of the motor/s (turn clockwise to increase speed). Adjustment
is carried out to establish the correct speed at the completion of opening and closing,
depending on the structure of the gate, or if there is any light friction that could compromise
the correct working of the system. The low speed is activated (DIP8 OFF) when the gate leaf
is 0.50-0.60 meters away from the complete close or open position.
ELECTRONIC BRAKE
If the low speed in approaching is disabled (DIP8 ON), is preferable turn the DIP7 ON to
enable at least the electronic brake that permits to win the gate leaf inertia when the gate
reaches the close or open limit switches.
ELECTRONIC BRAKE FOR FAST VERSION code BA03221 - BA03177:
The electronic brake is always enabled with FAST operators
The "weak version" of the electronic brake is enabled with the switch DIP7 OFF.
The "strong version" of the electronic brake is enabled with the switch DIP7 ON.
GRADUAL START
With DIP 9 in the ON mode, the gate starts to move gradually for 1 second only.
LED WARNING
DL1 - programming activated (red)
DL2 - radio code programming (green) (CRX version only)
DL3 - open limit-switch contact (NC) (red)
DL4 - close limit-switch contact (NC) (red)
DL5 - gate closing M1 (red)
DL6 - gate opening (green)
DL7 - photocell contact (NC) (red)
DL8 - safety strip contact (NC) (red)
DL9 - Pedestrian opening button (red)
POINT C - MOTOR ROTATION DIRECTION CHECK
This operation is meant to help the installer during the installation (commissioning) and for
further future controls.
N.B.: During this procedure, safety photocells and safety strip are not active.
1 - Unlock the operator with the Manual Release, install the limit switch plates, swing open
the leaf about halfway and lock the operator.
2 - Turn DIP1 to ON position, LED DL1 starts blinking
3 - Press and hold the PROG button, the gate will open or close. Release the button and the
gate will stop. Press and hold again, the gate will move in the opposite direction.
The K control board has two movement leds
- DL6 the GREEN led for OPENING
- DL5 the RED led for CLOSING
4 - Press and hold the PROG button, if the gate opens with the green led on then you may
proceed to step 5.
If the gate moves in the wrong direction compared with the movement leds:
- turn OFF the main AC power
- reverse the V and W motor cables position (the blue motor cable must be
always in the U position)
- reverse the limit switch wires marked LSO and LSC
- turn ON the main AC power and check again the motor direction
5 - After 2 seconds motor starting and for the next 10 seconds motor working, the torque
control is automatically activated. Set the motor torque by the TORQUE Trimmer which
varies the output voltage to the head of the motor (turn clockwise to increase torque).
6 - After other 10 seconds motor working, the low speed control is automatically activated
(DIP8 OFF). Set the motor low speed by the LOW SPEED Trimmer to select the gate leaf
low speed in approaching.
FOR FAST VERSION code BA03221 - BA03177:
5 - After 1 sec. and within 5 sec. of continuous work, both in closing or opening,
the electronic clutch intervenes automatically. Adjust the force of the electronic
clutch by turning the appropriate trimmer TORQUE.
6 - After 5 sec. of continuous work, both in closing or opening, the deceleration
is automatically activated (if DIP8 OFF). Adjust the low speed during the
deceleration by turning the appropriate trimmer LOW SPEED.
7 - Press and hold the PROG button to close completely the gate. Turn DIP1 to OFF, the RED
led DL1 will stop blinking.
POINT D - PROGRAMMING
N.B.: All the safety devices (photocells and safety strip) will be active, so they must be
properly installed and connected to the control board. Any changing of the safety
devices input state, will stop the procedure that must be repeated from the beginning.
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PROG. Button, motor opens.
4 - Once reached the open position, the open limit switch will cut out motor and the gate
travelling will be stored. The gap of time between now (stop of motor) and the next
pressing of the PROG. button (see step 5 below) will be then stored as waiting time for
Automatic Closing feature.
5 - Press PROG. button, gate closes and the Automatic Closing time is stored (see DIP3
function to enable or disable the Automatic Closing feature).
6 - The LED DL1 will turn OFF, signalling exit from the Point D procedure.
Closing of the gate will be carried out at normal speed and only on approaching total
closing at low speed (depending on the adjustment of LOW SPEED trimmer).
7 - When the gate leaf reaches the close limit switch plate, the motor stops.
8 - Turn DIP2 to OFF position.
POINT E - PROGRAMMING OF PEDESTRIAN OPENING (#)
N.B.: All the safety devices (photocells and safety strip) will be active, so they must be
properly installed and connected to the control board. Any changing of the safety
devices input state, will stop the procedure that must be repeated from the beginning.
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts blinking slowly
4 - Press the pedestrian pushbutton PED. BUTT, the gate opens
5 - When the gate leaf is opened enough for the pedestrian crossing, press the pedestrian
pushbutton PED. BUTT to stop the travel (thus defining the opening stroke of the
motor). The gap of time between now (stop of the motor) and the next pressing of the
PROG. button (see point 6 below) will be stored as waiting time for Pedestrian Automatic
Closing feature.
6 - Press the pedestrian pushbutton PED. BUTT, gate closes and the Pedestrian
Automatic Closing time is stored (see DIP3 function to enable or disable the Automatic
Closing feature).
7 - Turn DIP1 to OFF position.
8 - Turn DIP2 to OFF position.
POINT F - PROGRAMMING RADIO CODES FOR COMPLETE OPENING
(UP TO 30 CODES - ONLY FOR CRX MODELS)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press the remote control button (normally channel A) within the 10 seconds proscribed. If
the remote control has been correctly programmed, the DL2 LED (green) will flash once.
4 - The code programming time resets automatically so that you can programme the next
remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button briefly. The
red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 2 to OFF.
7 - You have completed the procedure
PROCEDURE FOR DELETING ALL RADIO CODES USED ONLY FOR COMPLETE OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.