Descargar Imprimir esta página

jbc DR 3600 Guía De Referencia página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
To empty the solder tin deposit and change
the filter.
For this, the lid needs to be unscrewed and
first the tin deposit and then its spiral must be
removed to clean the inner part of the deposit
with a brush.
-
The condition of the filter must be checked
and replaced if dirty or damaged.
-
The deposit needs to be inserted with
spiral filter put into place. Then the whole
must be closed by screwing the lid shut.
Filter Ref.0006609
Placement instruction of the spiral in the tin
deposit.
The spiral needs to be positioned between the
2 lines marked on the tin deposit.
Spiral
Change the heating element of the Micro
Desoldering iron (Ref. 3600010)
Lid
-
To perform this operation, the deposit
lid needs to be loosened.
Lid
Spiral
Brush
Ref. 0006608
Deposit
Fixing screw
Heating element
Ref. 3600010
-
Undo the screw indicated in the picture
and remove the heating element.
-
Place the new heating element.
Alignment
Important.
-
For a good connection it is essential to insert
the cartridge lining up the mark
handle screw cap.
Fixing screw
-
Tighten the screw indicated in the picture
then tighten the lid.
JBC reserves the right to make technical changes without prior
notification.
3
with the
Lid

Publicidad