3 – SPECIFICATIONS
Bridge Resistance
Output Sensitivity
Static accuracy
Stability of zero offset with temperature
Overload Capacity
Operation to specification over a temperature range of
Operation to reduced specification over a temperature range of -10 to 60ºC
Humidity non-condensing
Ingress Protection of Transducer (except connector)
Models
Model
DWT 30-10
DWT 50-10
DWT 70-13
DWT 100-13
DWT 150-13
DWT 250-13
DWT 400-20
DWT 1000-25
4 – INTERFACE
View of transducer connector:
01/2010
Capacity
Reference
30 Nm
615 165 544 0
50 Nm
615 165 545 0
70 Nm
615 165 546 0
100 Nm
615 165 547 0
150 Nm
615 165 548 0
250 Nm
615 165 549 0
400 Nm
615 165 550 0
1000 Nm
615 165 551 0
A
MOSI
B
CLOCK
C
CS.MEM
D
CS.ADC
E
+ 15V
Connecting cable:
350 ohm
2mV/V
±0.35% of FSD
±0.1% of FSD/ºC
25% of FSD
5 to 40ºC
10 to 75%
IP40
F
- 15V
G
CDE.CAL
H
MISO
J
CS.ANGLE
K
AGN
2m (6159174300)
5m (6159174330)
Spiral 2m fully extended (6159174320)
4 (68)