Optimum spraying.
The power setting and piston size of the volumeSPRAY allow it to deliver up to 350
grams of water per minute. The sprayer is designed to spray only medium to high
viscosity food materials between 30 - 100 DIN/sec (too powerful for thin materials).
This is sufficient to lightly coat circa 7 - 12 m² using a surface pattern of about 10
cm, sprayed at approximately 30 cm distance.
Before starting, turn the power knob completely to the left. This is the maximum
power setting and after a few seconds it will allow sufficient suction for spraying
the material. Adjust the power knob as required until the sprayer demonstrates a
fine spray and makes an even tone.
Maintain a constant distance and smooth movement.
Avoid shaking the gun or sharp movements as this will cause droplets.
Varying the speed of arm movement, the height and number of coatings, will vary
the effect and thickness of sprayed material.
It is recommended to start and stop the sideways movement off the product and
only press the power button when over the product. This helps reduce the volume
being sprayer at the turning point.
The supplied R8 round nozzle provides a wider pattern, particularly for thicker
materials. An R6 nozzle may also be used for thinner materials.
If you want to spray from below, you may rotate the nozzle extension – however
- only rotate in a clockwise direction (when viewed from the front), otherwise you
will loosen the nozzle extension. The easiest method of adjusting the nozzle
direction is from the right side, hold the pump housing firmly with your left hand
and move the nozzle extension with your right hand.
4. CLEANING
IMPORTANT: Always remove the electric parts before washing the gun. These parts
should never be exposed to liquids. Always clean immediately after use.
For external cleaning, simply wipe down the outside of the sprayer with a dish soap.
For internal cleaning, we recommend to spray half a container of very hot water
through and then clean the individual parts using a suitable dishwashing detergent.
Careful use of a soft pipe cleaning brush is also recommended. Care should be taken
not to damage the cylinder by using abrasive or sharp tools. If available, blowing air
through the nozzle and suction tube can ease the cleaning process. Rinse thoroughly
thereafter with hot clean water.
5