PSR2 control board (PSE3000 - PSU3000 - PSC3000) - description
1
2
3
4
5
6
1 -
Terminals for connection to the transformer
2 -
1.6 A circuit protection fuse
3 -
Barcode printer connector
4 -
3.15 A line protection fuse
5 -
Terminal for 230 VAC control board * power supply.
6 -
Terminals for connecting internal heating unit power
supply.
7 -
Contact thermostat to control heating unit (see page 44)
8 -
24 VAC output
9 -
Ticket request pushbutton contact
10 - Terminals for connecting the magnetic coil (only for PSE
unit to activate token)
11 - Terminals for connecting to PSCAR1 control board (PSE/
PSU/PSC display)
12 - Terminals for connecting to end ticket paper photocells
(PSE)
13 - Terminals for connecting to RBMP1 or to another PSR2 or
* The cross-section of the double insulated power cable (230 V) depends on the specifications and dimensions of the
system, and must not be less than 2.5 mm². Before connecting the device, disconnect the mains power supply to the system.
PS BARCODE -
23
8
7
Hardware and connections
20
22
21
19
9
10
11
to an REM
14 - Terminals for connecting devices to be controlled
(automations)
15 - Connection to TSP00 sensors
16 - Connectors for signal decoding cards (R700)
17 - Connector for scanner
18 - 10 position Dip Switch
19 - "active circuit" LED signal lights
20 - 2 position Dip Switch - N.B.: leave the default setting
unchanged (dip 1=ON; dip 2=OFF)
21 - Connector for coin reader (PSC3000); micro-switch (PSE)
22 - Control board LED power signal
23 - Connector for barcode printer
18
12
13
17
16
15
14