V to the input end.
d) AC voltage measurement
1. Insert the black probe into the "COM" jack and the red probe into the "
2. Set the function switch to "
button until a " ~ " symbol appears on the screen.
3. Connect the probes to the two ends of the power or circuit to be measured.
4. Read the reading.
Note
To avoid electric shock or damage to the meter, do not apply a voltage greater than
600V to the input.
e) DC measurement
1. Remove all the probes from the meter, and then set the function switch to the
required current measuring position.
2. If the meter reading is not zero before the measurement, please press the "
button to make the screen display zero before using the head to clamp the measured
lead.
3. Press the trigger, clamp the conductor to be measured with the head, and then slowly
release the trigger until the head is closed completely.
4. Take readings on the screen.
Note
Ensure the conductor to be measured is clamped in the center of the head. The meter