Electrics
Operating voltage
Central connection
Rated value
Individual connection:
Rated value (tolerance)
Non−standard
2)
voltages
(tolerance)
Power consumption
Central connection
High current phase
Holding current phase
4)
Break time
Rate of change
Individual connection
Rated output of the coil
1)
Rated value, protected against incorrect polarity (permitted toler.)
2)
Use of the M8 and M12 central plug for these voltage ranges is not
permitted.
3)
For control voltages of AC 110 V or AC 230 V it is mandatory that
the protective conductor is connected with protective earth.
4)
To achieve the high current phase
30
1)
Valve type VSVA−B−...:
DC 24 V (tolerance ±10 %)
Valve type MN2H... and JMN2H...:
DC 24 V (+10/−15 %)
For valves of type ...−12DCA:
DC 12 V (+10/−15 %) and
AC 24 V (+10/−15 %)
For valves of type ...−110AC
AC 110 V (±10 %)
For valves of type ...−230AC
AC 230 V (+10/−15 %)
DC 24 V (valve types VSVA−B−...)
2.55 W
1.0 W
Min. 3.4 ms
4)
Min. 0.4 V/ms
(min. power supply requirement)
Valve type MN2H... and JMN2H...:
DC 12 V
DC 24 V
1.5 W
per coil
AC 24 V
AC 110 V
3 VA
3 VA
Festo VSVA−B−...−A... 0411b English
3)
:
3)
:
AC 230 V
3 VA