Function and application
A built-in pressure sensor records the pressure at the air supply port. The electronic control unit com
pares the pressure value with the setpoint value. An analogue, electrical signal is issued corresponding
to the output pressure. If the actual value differs from the setpoint value, the regulating valve is actu
ated until the output pressure reaches the setpoint value.
The MPPES-... is designed to control pressure proportionately to a specified, electrical setpoint value.
Note
Make sure that high-frequency radiation (e.g. by radio sets, mobile telephones or
other interference-emitting devices) is kept away from the MPPES-....
In this way you will avoid increased tolerances in the output pressure (for further
information refer to the EMC specifications in the Technical data chapter).