2.8.
Sauna heater safety clearances
Effect
kW
6,8
9,0
10,5
Corner and wall installation: The sensor OLET 19 must be installed to ceiling in the side-line to the out side
Wall support
attaching the
heater to the wall or
benches
NOTE !
Mid-floor installation: If the heater is placed more than 60 mm from the wall the installation type is always a
mid-floor installation. The heater must be attached to the benches or to a similar structure using a wall support.
OLET 19
Figure 2 Safety clearances
Saunaroom
Volume
Height
min.
max.
m³
m³
min. mm
5
9
1900
8
13
1900
9
15
1900
Table 1 Safety clearances