INSTALL DUCT COLLAR
1. Attach the duct collar onto the hood; it must
be attached by means of 2 mounting screws
(3,9x9,5 mm Pan Head).
2. Remove the tape located on the damper.
WIRING
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box.
2. Secure the conduit to the wiring box through
a conduit connector.
3. Make electrical connections. Connect white
to white, black to black and green to green.
4. Replace wiring box cover and screws. Make
sure that wires are not pinched between
cover and box.

CONNECT DUCTWORK

Ducted Configuration
1. Use (2) screws (4.8x38mm) and wall
anchors to secure flue mounting bracket
to the ceiling or wall as shown.
2. Use 6" round metal duct to connect the duct
collar on the hood to the ductwork above.
3. Use duct tape to make all joints secure and
air tight.
4. Connect the upper section of decorative flue
to the bracket with screws provided
(3.9x6mm).
5. Slide the lower section of decorative flue
downward, until it fits properly around hood.
FLUE MOUNTING
BRACKET
- 7 -
MOUNTING SCREWS
(3.9x9.5mm)
REMOVE THE
TAPE
WIRING BOX COVER
DUCT
COLLAR
FASTEN FLUE
TO BRACKET
WITH SCREWS
(3.9x6mm)
DECORATIVE
FLUE
DUCT TAPE
6" ROUND
METAL DUCT