Plastic
Guard
Plunger
Arm
Hook
Trip Lever
Install New Trip Lever
Remove the tank cover from the toilet.
IMPORTANT! Do not drop the nut into the vitreous tank. If the nut
falls below the water reservoir, it is not accessible.
Loosen and remove the nut securing the trip lever to the tank by
turning it clockwise. The nut has left-hand threads.
Remove the existing trip lever.
From outside the tank, insert the replacement trip lever arm
through the hole in the tank, sliding the trip lever arm through
the nut.
When seating the bushing against the outside of the tank,
position the trip lever arm below the plunger arm.
Hand tighten the nut turning it counterclockwise. The nut has
left-hand threads.
Check the gap between the top surface of the actuator and the
bottom of the plunger arm. The acceptable range should be
between 1/16" (2 mm) and 1/8" (3 mm).
NOTE: If less than a 1/16" (2 mm) gap is provided, the toilet will
not shut off. More than a 1/8" (3 mm) gap may cause the flush to be
too short.
Kohler Co.
Plunger
Back
Arm
Locking
Tab
Locknut
Plunger
Arm
Trip Arm
3
Actuator
Front Locking Tab
1045428-2-A