Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.2.6. FREQUENCY
In the Hz% setting
Input voltage ≥ 2 V
ac
Range
10 Hz
Resolution
0,001 Hz
Intrinsic
uncertainty
In the A or V setting
Maximum input voltage 600 V
Input voltage ≥ 600m V
Measurement range
Resolution
Intrinsic uncertainty

3.2.7. DUTY CYCLE

Measurement range
Resolution
Intrinsic uncertainty
In the Hz% setting
Frequency: 1Hz to 10 MHz.
Input voltage ≥ 2 V
ac
In the A or V settings
Frequency: 40Hz to 100 kHz.
Input voltage ≥ 600 mV
3.2.8. TEMPERATURE
Measurement range
Resolution
Intrinsic uncertainty
. This voltage increases with the frequency to be measured.
100 Hz
0,01 Hz
.
ac
. This voltage increases with the frequency to be measured.
ac
100 Hz
0,01 Hz
0.1-99.9%
0.1%
. This voltage increases with the frequency to be measured.
. This voltage increases with the frequency to be measured.
ac
-20°C ... +1000°C
±(3% R ±3 pt)
1 kHz
10 kHz
0,1 Hz
1 Hz
± (1% R ± 5 pt)
1000 Hz
10 kHz
0,1 Hz
1Hz
±(1.5% R ±5 pt)
±3%
1°C
21
100 kHz
1 MHz
10 Hz
10 Hz
100 kHz
10Hz
10 MHz
100 Hz

Publicidad

Tabla de contenido
loading

Tabla de contenido