Generator Shut Down; Low Oil Level Shutdown System; Using The 12 Vdc Battery Charger - Generac iX Serie El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Figure 3-8.Choke Position
7. Firmly grasp recoil handle and pull slowly
until increased resistance is felt. Pull rap-
idly up and away.
8. When engine starts, move choke knob to
1/2-choke position until engine runs
smoothly, then to OFF position. If engine
falters, move choke back to 1/2-choke
position until engine runs smoothly, then to
OFF position.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full Choke and
repeat starting instructions.
IMPORTANT NOTE: Do not overload the
generator. Also, do not overload individual
panel receptacles. If the Overload LED
(red) is lit attached devices stop operating,
stop engine. Reduce loads before restart-
ing engine. Read "Know Generator Limits"
carefully.

Generator Shut Down

Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. Turn fuel valve to the OFF. See
.
Figure 3-9.Fuel Valve OFF
10
CAUTION
(000136)
Figure

Low Oil Level Shutdown System

The engine is equipped with a low oil level
sensor that shuts down the engine automati-
cally when the oil level drops below a speci-
fied level. The engine will not run until the oil
has been filled to the proper level.
If the engine shuts down and there is sufficient
fuel, check engine oil level.
Using the 12 VDC Battery
000727
.
Charger
The 12 VDC receptacle may be used to
recharge 12 VDC automotive batteries only.
The DC charging output is not regulated. The
circuit protector does not prevent over-
charging a battery.
1. Connect the charging cable to the genera-
tor first, then the battery. ALWAYS connect
the red lead to positive (+), and the black
3-9.
to negative (-).
2. Keep the FlexPower™ switch in the OFF
(O) position.
3. Start generator and use as normal.
Charging time will vary with battery size
and condition. Check voltage at battery
terminals once the charging cable has
been unplugged, or generator has been
shut down.
NOTE: This receptacle cannot recharge 6 Volt
batteries and cannot be used to crank an
engine having a discharged battery.
000725
WARNING
WARNING
Risk of burn. Battery contains electrolyte solution
which can cause burns and blindness.
If electrolyte contacts skin or eyes, flush with
water and seek immediate medical attention.
WARNING
CAUTION
Do not make battery connections
in reverse. Doing so will result in
equipment damage.
Owner's Manual for Portable Generator
(000137a)
(000163)
(000138a)
(000167)