Television
Toaster
Weed Trimmer
* Allow 3 times the listed watts for starting these
devices.
Transporting/Tipping of the Unit
Do not store or transport the unit at an angle
greater than 15 degrees.
Starting Pull Start Engines
Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
IMPORTANT
NOTE: Electronic
requires 10V minimum at battery connec-
tions for pull starting. The engine will not
start unless the battery connections have
the required voltage for the electronics and
fuel pump. If the fault indicator light
flashes rapidly with key in RUN position,
the generator will not start. Charge battery
prior to starting.
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. Rotate key to RUN. The RUN light will stay
on. See
Figure
Figure 3-2. Rotate Key
Owner's Manual for Portable Generator
200 to 500
1000 to 1650
WARNING
CAUTION
3-2.
4. Firmly grasp recoil handle and pull slowly
until increased resistance is felt. Pull rap-
idly up and away.
Do not overload generator or individual panel
500
receptacles. These outlets are overload pro-
tected with push-to-reset circuit breakers. If
amperage rating of any circuit breaker is
exceeded, that breaker opens and electrical
output to that receptacle is lost. Read
porting/Tipping of the Unit
Starting Electric Start Engines
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting the engine.
2. Place generator on a level surface.
3. Rotate key to RUN, wait 1 second. Rotate
key to START until engine starts. See
ure
NOTE: The key will automatically switch to
RUN and the fault light will turn off.
Generator Shut Down
(000183)
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
(000136)
property damage.
system
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. Turn key to OFF.
Low Oil Pressure Shutdown
System
The engine is equipped with a low oil pressure
sensor that shuts down the engine automati-
cally when the oil pressure drops below speci-
fications.
If the engine shuts down and there is sufficient
fuel, check engine oil level.The engine will not
run if the oil is below proper level.
See Inspect Engine Oil Level.
005809
CAUTION
3-2.
CAUTION
Trans-
carefully.
(000136)
Fig-
(000136)
13