Finished Wall
Stud
Large Console
32-1/2" (82.6cm)
Small Console
33-1/2" (85.1cm)
From Finished Floor
Wall Bracing
(2x6 minimum)
1. Prepare the Site
Rough in the water supply lines and the drain piping.
-
Install a minimum of a 2x6 as a wall brace to provide support for
-
the wall clips. The brace should be the same length as the console
table and should be positioned 32 1/2" (82.6cm) from the finished
floor to the top edge of the board for the 42" (106.7cm) console and
33 1/2" (85.1cm) to the top edge for the 32" (81.2cm) console. The
center of the wall brace should be in line with the drain outlet.
Finish the wall.
-
Mark a centerline on the floor and wall.
-
Use the four lag bolts to install the wall clips, two for each wall clip.
-
Predrill 3/16" (5mm) holes for each lag bolt to avoid splitting the
2x6.
The wall clips for the 32" (81.2cm) console should be 29 3/4"
-
(75.6cm) from the floor to the bottom lag bolt and 26" (66cm) apart,
13" (33cm) each side from center.
The wall clips for the 42" (106.7cm) console should be 29 5/16"
-
(74.5cm) from the floor to the lower lag bolt and 34" (86.4cm) apart,
17" (43.2cm) each side from center. Make sure the wall clips are level.
Kohler Co.
1-3/16"
(3cm)
17" (43.2cm)
13" (33cm)
17" (43.2cm)
13" (33cm)
29-5/16" (74.5cm)
(42" console)
29-3/4" (75.6cm)
(32" console) (to
bottom lag bolt)
3
C L
A