16
16B
16F
16E
16D
16C
16 CLEANING AERATOR
Over time, the aerator in your faucet may become clogged with debris. To clean
the aerator, unscrew aerator housing (16A) from spray head (16B) using a 7 / 8 "
open ended wrench or adjustable wrench. Separate aerator housing (16C),
aerator basket (16D), flat seal (16E) and spring (16F). Once parts have been
cleaned, reassemble by reversing these steps.
17
17B
17A
17F
16A
17C
17D
17E
ENGLISH
17 TROUBLESHOOTING
Turn off water supplies and relieve pressure before working on your faucet.
Handle Removal:
Carefully pry off handle button (17A) using a small screwdriver or blade.
Using a Phillips screwdriver, Loosen screw (17B) and remove handle (17C).
Cartridge Replacement
Turn off water supplies and relieve pressure before working on your faucet.
Remove handle (17C) – see above. Remove the dome cap(s) (17D) by
unscrewing counter clockwise. Using pliers, unscrew the retainer nut (17E)
Carefully remove the cartridge (17F) by pulling it straight up and out Re-
assemble faucet by reversing steps
Retainer nut (17E) must be "wrench" tight. Hand tighten retainer nut (17E) until
flush to the surface of cartridge (17F). Wrench tighten 1/2 to 3/4 turn.
CAUTION: Maintenance
DISASSEMBLY
1.
Replacement parts may be available at the store where you
purchased your faucet.
2.
When replacement parts are not available, please write or
call Price Pfister Consumer Service.
3.
Always turn off water and relieve pressure before
working on your faucet.
NOTE: Trim Care
Cleaning Instructions:
For all handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents, or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain porcelain or other similar
substances are not acceptable for public areas or commercial
use. Installation of said trim is at user's risk!
1-800-PFAUCET (1-800-732-8238)
For Toll-Free Pfaucet information call
1-800-PFAUCET (1-800-732-8238)
or visit www.pricepfister.com