BELT OR BRUSHROLL REMOVAL AND REPLACEMENT

1.
CAUTION: TO REDUCE THE
RISK OF INJURY FROM
MOVING PARTS- UNPLUG
BEFORE SERVICING.
TOOL REQUIRED:
PHILLIPS SCREWDRIVER
For belt replacement (Part # 1-672260-001)
please call 1-800-321-1134 or visit www.royal-
Diagram 1
vacuums.com to locate a dealer nearest you.
Remove nozzle guard. Arrows
show location of screws.
1.
Remove power nozzle from
unit
3.
2.
To remove nozzle guard: turn
power nozzle over. Remove
the five (5) screws (Diagram1).
NOTE: The screws will fall out
when the power nozzle is flipped
over.
3.
Flip the power nozzle upright.
Gently lift the cover off.
4.
Lift and remove brushroll
(Diagram 3).
5.
Pull out broken belt and
Diagram 3
replace with new belt (Diagram
Lift and remove brushroll.
4). Loop belt around motor
shaft and end of brushroll (belt
should be on raised area of
5.
brushroll without bristles).
6.
Insert brushroll into side holder
#1 and then #2 (Diagram 5).
Rotate brushroll to make sure
belt is not twisted.
7.
Replace nozzle guard. Flip
cleaner over and replace the
five (5) screws (Diagram 6).
#2
Diagram 5
Insert brushroll into side holder
#1 and then #2.
2.
COVER
Diagram 2
Lift cover off power nozzle.
4.
MOTOR SHAFT
Diagram 4
Pull out broken belt and replace
with new belt.
6.
#1
Diagram 6
Replace nozzle guard. Flip power
nozzle over and replace the five
(5) screws.