1/4" Furring Strip
Stud
Drill 1/8" (3 mm) holes
through nailing-in flange.
Leveling shims should be
placed underneath bottom
support blocks if needed.
Attach drain to P-trap.
3. Prepare the Receptor
CAUTION: Risk of product or property damage. Do not support the shower receptor by the rim.
The weight of the shower receptor should be supported by the support blocks located under the
receptor.
CAUTION: Risk of product or property damage. If a watertight seal on the drain is not obtained,
water damage to the receptor bottom and the subfloor may occur.
Install the drain to the shower receptor according to the drain manufacturer's instructions. Follow
all local building codes, standards, and regulations.
Make sure the shower receptor is level on all sides. If the receptor is not level, shim as required to
level it.
Clean the shower receptor to reduce the risk of surface damage, then place a clean drop cloth or
other similar material into the bottom of the shower receptor.
Kohler Co.
Nailing-In
Flange
Screw or
Galvanized Nail
Subfloor
7
Check
level here.
Check
level here.
Edge of receptor should sit
flat on floor. Shim bottom
support blocks if needed.
1058614-2-C