STEP 3
Installation of the case in the wall opening
1. Position the case into the wall. Refer to chart on
page 1 for roomside projection. The rear (outside)
edge of the case should extend at least 1/4" beyond
the outside wall to be able to caulk properly and
prevent sealing the drain holes in the rear flange
of the case, and to facilitate easy installation of
an accessory drain, if desired. (If it is desired to have
the rear grille flush on the outside, a drip rail must
be installed under the case and caulking applied
between the drip rail and case.)
IMPORTANT:
Install case level from side to side
and with a slight tilt from front to rear. Use a level;
no more than a 1/4 bubble will be the correct case
slant to the outside.
2. Firmly secure the case to the wall structure.
Do not drill any holes in the bottom of the case.
Secure case through
side and/or top only
2" min. from
case bottom
3. Caulk the entire opening on the outside between
the case and the building exterior.
4. Caulk the entire opening on the inside between
the case and the building interior.
Use lintel, when required, to support brick and block
above the case.
NOTE:
Do not drill any holes in the case for electrical
connections.
Inside wall
STEP 4
Weatherproofing
Weatherproof gaps between the exterior and interior
walls and the case with caulking or equivalent
weatherproofing material.
Caulk*
Room
cabinet
Caulk*
NOTE:
*
It is critical to caulk around perimeter of
wall case on all four sides on the outside and the
roomside where it joins the building to prevent air
and water infiltration.
For installation in extra thick walls
1. The case should not be installed in a thick wall
where the case is recessed more than 3".
2. If the case is being installed in a wall where
the recess is 3" or less, flashing must be installed
under the case and extend up 2" on each side.
The flashing must include a drip rail as illustrated
in the figure below.
NOTE:
*
It is critical to caulk around perimeter
of wall case on all four sides where it joins the
building to prevent air and water infiltration.
3
Steel lintel
Caulk*
Case
Caulk*
Outdoor
grille
Case
Flashing
Caulk*
Drip rail
Outdoor
grille