ELECTRICAL REQUIREMENTS (230V/208V)
Provisions should be made to have the proper
electrical outlet near the case. All wiring should be
made in accordance with local codes and regulations.
The line cord will extend to a wall receptacle located
within the area shown in the table below.
A
Inside
Wall Receptacles
120V/115V 12 amp
"tandem" type
All wiring should be made in accordance with local
electrical codes and regulations.
See the Owner's Manual for how to connect electrical
supply.
NOTE:
Aluminum wiring in structure may pose
special problems—consult a qualified electrician.
B
MODEL
"A"
"B"
115V
47"
72"
230/208V
39"
65"
230V/208V 20 amp
"perpendicular" type
Specifications subject to change without notice
A Quality Product of GE Appliances
DRAIN KIT (optional)
If it is necessary to install a drain kit on this wall case,
the following kit is available:
RAD4A1 External Drain
This external drain will carry condensate water away
from the unit and the building.
To install:
1. Cut off the solid end of the rubber plug (approx.
1/8"). Be sure the hole is open through the length
of the plug. Insert the plug through the drain hole
in the corner of the cabinet. (Immersing the rubber
plug in denatured alcohol or soap suds will make
this easier.)
2. Insert the drain fitting into the rubber plug.
3. Attach a field-supplied drain tube to the drain
fitting. Install strain relief clamps to the drain
tube to prevent leaks due to mechanical strain
or vibration.
4. A non-hardening sealant should be applied where
the rubber plug fits into the cabinet and where
the drain fitting meets the rubber plug.
5. If metallic tubing is used as a drain tube, a short
length of rubber or plastic tubing should be used to
connect the drain fitting to the drain tube. This will
prevent mechanical strain to the drain fitting and
reduce vibration transmission from the unit to
the drain tube.
6. If an architectural rear grille is used in this
installation, it is necessary to cut a small triangular
section from the lower right corner of the grille to
provide adequate space for the drain tube.
NOTE:
It may be desirable or necessary to install
the drain kit on the case prior to installing the case
into the wall.
4
Rubber
plug
Drain
fitting
Cabinet