Pneumatic interface type
General technical specifications
of the CPX terminal
Protection class as per EN 60529 IP65, in fitted state
Operating voltage supply
Rated voltage
Internal current consumption
at 24 V (internal electronics)
Load voltage for the valves
Rated voltage
Internal current consumption
at 24 V (internal electronics)
Diagnostic message under
voltage V
VAL
Digital outputs (valve solenoid
coils)
Rated load voltage
Intended for pneumatics
Short circuit protection at
valve output
Isolation
Electrical isolation
Between the channels
To V
EL/SEN
22
VABA−10S6−x1
See CPX system manual
V
(electronics/sensors)
EL/SEN
24 V DC ± 25 %
Typ. 15 mA
V
(valves)
VAL
24 V DC ± 10%
Typ. 30 mA
21.6...21.5 V
Max. 32 outputs
V
VAL
VTSA (ISO, type 44)
Yes (electronic),
response threshold > 1.0 A
Tested with 500 V DC
None
Depends on manifold sub−base
Festo CPX−GP−..., VABA−... 0503a English