Tank Bolt
Rubber
Spacer
Models K-3493 and K-3505
3. Install the Tank
CAUTION: Risk of product damage. Overtightening the tank
bolts may cause breakage or chipping of the vitreous china.
NOTE: Do not remove the pre-assembled tank bolts from the bottom
of the tank. The nuts and washers for securing the tank to the bowl
are packaged separately.
Verify that the factory installed rubber spacers are in place on the
tank bolts.
For Models K-3493 and K-3505 Only:
IMPORTANT! DO NOT remove the rubber spacers before
assembling the tank to the bowl.
For Model K-3554 Only:
IMPORTANT! To achieve a watertight seal, the rubber spacers must
be removed before assembling the tank to the bowl.
Remove the three rubber spacers from the tank bolts. Discard the
rubber spacers.
For All Models:
Position the tank on the bowl by centering the gasket on the bowl
inlet.
Assemble the washers and nuts to the tank bolts.
Kohler Co.
Gasket
Remove
rubber
spacers.
Model K-3554 Only