16. M
AINTENANCE AND SERVICING
16.1. Service precautions
In order to ensure optimal operation of the unit, a number of checks
and inspections should be carried out on the unit at regular intervals,
preferably yearly.
This maintenance shall be carried out by the installer or service
agent.
DANGER: ELECTRICAL SHOCK
See "2. Safety considerations" on page 2.
NOTICE
Touch a metal part by hand (such as the stop valve) in
order to eliminate static electricity and to protect the PCB
before performing service.
CAUTION
Do not rinse the outdoor unit. This may cause electric
shocks or fire.
DANGER: DO NOT TOUCH PIPING AND INTERNAL
PARTS
See "2. Safety considerations" on page 2.
■
Do not touch live parts for 10 minutes after the power
supply is turned off because of high voltage risk.
■
Make sure that the power supply is turned off before
performing the maintenance work. The heater of the
compressor may operate even in stop mode.
■
Please note that some sections of the electric component box
are extremely hot.
■
Make sure you do not touch a conductive section.
■
After measuring the residual voltage, pull out the outdoor fan
connector.
■
The outdoor fan may rotate due to strong backblow wind,
causing the capacitor to charge. This may result in an electric
shock.
After maintenance, make sure the outdoor fan connector is
connected again. Otherwise, the unit may break down.
16.2. Service mode operation
Refer to the service manual to carry out any service mode operation.
17. D
ISPOSAL REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with applicable legislation.
Installation manual
18
18. U
NIT SPECIFICATIONS
18.1. Technical specifications
Casing material
Dimensions h x w x d (mm)
Weight
(kg)
Operation range
• cooling (min./max.)
(°C)
• heating (min./max.)
(°C)
• domestic hot water
(°C)
(min./max.)
Refrigerant oil
Piping connection
• liquid
(mm)
• gas
(mm)
(a) See operation range data information sheet for detailed information.
18.2. Electrical specifications
Phase
Frequency
(Hz)
Voltage range
• minimum
(V)
• maximum
(V)
RRLQ_V3
RRLQ_W1
Painted galvanised steel
1345 x 900 x 320
114
10/46
(a)
–25
/35
(a)
–25
/35
Daphne FVC68D
9.52
15.9
V3
W1
1~
3N~
50
50
207
360
253
440
RRLQ011~016CAV3+W1
Outdoor unit for air to water heat pump
4PW57794-1 – 10.2010