Read the operating instructions and the enclosed brochure
!
„Guarantee and additional notices" completely. Follow the
instructions they contain. This document must be kept in a
safe place and passed on together with the device.
Function/Application
Contactless test device for localising electrical voltage (230 V AC)
in cables, sockets, lampholders and fuses. Visual and acoustic
signals indicate whether a voltage is present.

Safety instructions

• The device must only be used in accordance with its intended
purpose and within the scope of the specifications. Modifications
or changes to the device are not permitted, this will otherwise
invalidate the approval and safety specifications.
• In overvoltage category III (CAT III - 1000 V), the voltage between
the test device and earth must not exceed 1000 V.
• Do not expose the device to mechanical stress, extreme
temperatures or significant vibration.
• If you are working with voltages higher than 25 V/AC / 60 V/DC,
exercise extreme caution. Touching the electrical conductors at
such voltages poses a risk of life-threatening electric shocks.
• If the device comes into contact with moisture or other conductive-
residue, work must not be carried out under voltage. At and above
voltages of 25 V/AC / 60 V/DC, the presence of moisture creates
the risk of life-threatening electric shocks. Clean and dry the device
before use. When using the device outdoors, make sure that the
weather conditions are appropriate and/or that suitable protection
measures are taken.
• Before taking any measurements, make sure that both the area to
be tested (e.g. a line), the test device and the accessories used
(e.g. connection cable) are in proper working order. Test the device
by connecting it to known voltage sources (e.g. a 230 V socket in
the case of AC testing). The device must no longer be used if one
or more of its functions fail or the battery charge is weak.
• Observe the safety precautions of local and national authorities
relating to the correct use of the device and any prescribed safety
equipment (e.g. electrician's safety gloves).
• The measuring tools and accessories are not toys.
Keep out of reach of children.
Symbols
Warning about hazardous electrical voltage:
Unprotected live components inside the device
housing are capable of posing a risk of electric
shock.
Protection class II: The test device has reinforced
or double insulation.
ActiveFinder