How to proceed:
1. Completely open the stop valves at the inlet IN and
outlet OUT.
2. Press the start button several times in quick succes-
sion until the filter starts filling with water.
3. Wait until water is visible in the hose to the outlet
pipe.
CLEANING AND MAINTENANCE
W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocution.
Switch off the appliance, disconnect the power plug
and secure the appliance from being switched on
again before starting any work.
After completing all work, restore all prerequisites
for start-up.
Maintenance intervals
Components
Tetra FF Filter Floss Pad
Tetra CF Carbon Filter Me-
dium
Tetra BB Bio Filter Balls
Tetra BF Biological Filter
Foam
Tetra CR Ceramic Filter
Rings
Impeller
Inspection
–
–
Every 12 months
Every 6 months
Every 12 months
–
4. Connect the plug of the filter to the power socket.
–
The pump in the motor head will switch on auto-
matically.
5. Set the flow rate.
–
Set the desired flow rate with the stop valve at the
inlet IN.
–
The stop valve at the outlet OUT remains com-
pletely open.
Cleaning
–
–
In the event of an obstruc-
tion due to extreme soiling
When dirt is visible on in-
spection
In the event of an obstruc-
tion due to extreme soiling
If the motor is not working
or the water flow is reduced
EN
Replacement
Monthly
Every 2 to 4 weeks
If the dirt on the surface
cannot be removed by rins-
ing
Every 12 months
If the dirt on the surface
cannot be removed by rins-
ing
–
9