Honda Petrol Engine
1.
Open the fuel tap by moving the fuel ON / OFF lever fully to the right.
3.
Turn the engine ON / OFF switch clockwise to the 'I' position.
4.
Set the throttle to the idle position by moving the throttle lever fully to the right. Do not
the right.
the '0' position.
Hatz Diesel Engine
1. Turn ON the fuel by moving the fuel ON/OFF lever fully to the right.
2. Set the engine speed control to start.
hands.
the engine stops.
Hatz Diesel Engine (Electric Start)
2. Turn start key to position 'II'
remain in this position during operation. The battery charge and oil pressure warning lights
musst go out immediately after starting. Indicator light '1' is on when the engine is in
operation.
engine and trace the cause of the problem.
Never operate the electric starter when the engine is running or coasting to a standstill. There is a risk of
broken starter pinion or ring gear teeth. Never stop the engine by moving the decopression lever.
CAUTION
During breaks in work or at the end of theworking period, keep the starting handle and starting key in a
safe place, out of reach of unauthorised persons.
6. Always turn the start key back to position '0' before re-starting the engine. The repeat lock prevents the starter motor from
engaging and possibly being damaged whilst the engine is still running.
7. Move speed control lever to '1' back to the STOP position.
STOP direction. Hold it there until the engine has stopped.
10. Turn the key to the 0 position and pull it out. The lights must then go out.

Start And Stop Procedure

ON by moving the choke lever fully to the
OFF position by moving it to
ON / OFF switch anticlockwise to
15
GB
Throttle Lever
Choke Lever
Fuel ON/OFF
Lever.