L400_10spr.qxd
31.07.2008
Function
Once the sensor light fixture
has been wired up and
approx. 10 sec.–max. 15 min.
10 – 30 W
10
13:51 Uhr
Seite 11
fastened to the wall support,
Three settings can now be
it can be switched on.
made on the light fixture's
sensor lens.
a. Lighting controller
(The unit is shipped with a
(threshold)
factory setting for daytime
operation.) When adjusting
The desired light threshold
the sensor light fixture
can be adjusted continu-
detection zone and for a
ously from about 2 lux to
performance test during
2,000 lux. The adjusting
daylight, the adjusting
screw turned clockwise all
screw must be turned
the way equals daytime
clockwise all the way.
operation at approx. 2,000
lux; counter clockwise all
the way equals nighttime
operation at approx. 2 lux.
b. Switch-off delay
way equals maximum time,
(time setting)
approx. 15 minutes. (The
unit is shipped with a fac-
The period for which the
tory setting of the minimum
fixture should light up can
time.) We recommend set-
be adjusted continuously,
ting the unit to the minimum
from about 10 seconds to
time when adjusting the
15 minutes. The adjusting
SensorLamp's detection
screw turned clockwise all
zone or carrying out a per-
the way equals minimum
formance test.
time, approx. 10 seconds;
counter clockwise all the
Infinitely variable bright-
ness control (Watt-o-matic)
The following functions can
be controlled by means of
the dimmer control:
1) Adjusting screw turned
clockwise all the way
means that the sensor
3) Adjusting screw of dim-
light fixture is switched
off. Only when move-
ment is detected is the
light switched on at full
power.
2) By setting the adjusting
screw between center
position and turned
clockwise all the way,
the brightness of the
fixture in standby mode
can be adjusted continu-
ously between about
10 watts and a maximum
of 30 watts. This means
that when movement is
detected the light swit-
ches from 20 W main-
tained lighting, for
example, to maximum
output (60 W).
mer turned counter
clockwise all the way
and adjusting screw of
lighting controller turned
clockwise all the way: in
this setting, the Sensor-
Lamp is constantly on.
If there is an on/off
switch in the circuit, the
sensor light fixture can
be operated as a normal
light fixture.