Procedure for installing the kit on the following burners:
878T - 879T - 888T - 889T
Disconnect the burner from the power supply!
DANGER
➤ Loosen the fixing screw and remove the cover.
➤ Release the electrical panel to allow the kit to be more easily
installed, referring to the operations described in the burner's
installation and instruction manual.
➤ Assemble the kit as shown, removing the fastening bracket
1)(Fig. 3).
➤ Fix the kit using the same screw 2)(Fig. 3).
➤ Carry out the internal wiring on the burner's terminal board
(Fig. 4).
➤ When the installation is finished, put back the electrical
panel, secure the cover and switch on the burner.