TECO 100 Variant Manual De Instrucciones página 49

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

SUPPLY
400/3/50
400/3/60
230/3/50
230/3/60
200/3/50
200/3/60
240/1/50
230/1/50
220/1/60
115/1/60
CAUTION
Do not remove or modify any parts of this equipment except in the case of service operations.
DANGER
When the machine is disconnected from the air supply system, the devices marked with the
warning sign shown above may remain pressurised.
- The filter+regulator+lubricator is equipped with a semiautomatic condensation drain device. This
device operates automatically whenever the compressed air supply to the machine is cut off. Drain
the condensation manually (push-button C, fig. 35) when the level exceeds the mark X, fig. 35.
- Clean the top plate of the turntable every week: remove any accumulated dirt and clean with
environmentally-friendly solvents.
- Monthly checks:
• Clean the arms of the tool-carrying head, the bead breaking unit and the relative travel screws
with environmentally-friendly solvents only. Lubricate.
• Check the oil level in the air lubricator (fig. 35) and, if necessary, top up with non-detergent SAE20
oil to the indicated level Z.
• Clean with a dry cloth. Avoid contact with solvents.
• Check the oil flow-rate through the transparent cover K (correct flow-rate: 1 drop of oil every 4
bead breaking cycles). Adjust if necessary by turning the set screw Y fig. 35.
CAUTION
Keep the working area clean.
Never use compressed air, jets of water or solvent to remove dirt or deposits off the machine.
When cleaning, take care not to create and raise dust as far as possible.
User Manual TECO 100 Variant
CABLE TYPE
FROR 450-750V
UNEL 35011
FROR 450-750V
UNEL 35011
UL 1569 300V
105°C
NR OF WIRES
3 - phase
1 - grounding
1 - phase
1 – neutral
1 - grounding
1 - phase
1 – neutral
1 - grounding
WIRE SECTION
1mm
2
1,5mm
2
AWG 14
49

Publicidad

Tabla de contenido
loading

Productos relacionados para TECO 100 Variant

Tabla de contenido