Before installing the light fixture under an eave, the
sensor head must be rotated as shown in the next
two steps for proper operation and to avoid the risk of
electrical shock.
IMPORTANT: For proper under-eave operation, install
light shield (included). See Light Shield Installation
for details.
For eave mount only:
1. Swing the sensor head towards the clamp screw
joint.
Clamp Screw
2. Then rotate the sensor head clockwise 180° so the
controls face down.
Light Shield
Opening
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
598-1309-02
Controls
Controls
Controls
Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
1. Remove the existing light fixture.
2. Install mounting strap to junction box using screws
appropriate for your junction box.
3. The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
4. Thread all fixture wires through the large holes in
the gasket as shown.
5. Connect the junction box wires to the light fixture
wires as shown. Twist together and secure with
wire connectors.
Black to Black
Mounting Strap
Connect any fixture ground wire(s) to the junction
box ground wire.
3
White to White
Gasket
Rubber Plug
Mounting Bolt