10 seconds, (indicated by the flashing LED); after 10 seconds, the control unit returns to
its original status.
The SET key: this programs the information according to the type of function previously
selected with the SEL button. IMPORTANT: The function of the SET key can be replaced
with the radio control, if programmed previously (CODE led on).
MAIN MENU
The control unit is supplied by the manufacturer with the possibility of selecting a number of
important functions.
———————————— –––
Led Reference
Led off
1) CODE
No code
2) LAMP/CORT.
Flashing
3) T. MOT.
Motor time 30 sec.
4) T. PAUSA
No auto close
1) CODE: (Programming the Radio controls and/or Transponder)
The control unit can store up to 120 different Radio Controls, Transponders, Digital key-
boards, Smartphones.
Programming Transponders, Keyboard or Smartphone NFC codes:
The devices are programmed as follows: press the SEL key, the CODE LED will start
flashing and at the same time move the transponder nearer to the BeSAFE Reader New,
activate the BeSafe KeyBoard or move the Smartphone nearer to the BeSAFE NFC Reader,
the CODE LED will be lit and steady for a moment indicating it has been stored; then the
CODE LED will continue flashing for 10 seconds while waiting for another device to be
stored, after which it will exit the programming mode.
Programming the radio control with 1 or 2 Keys.
The radio control transmission codes are programmed as follows: press the SEL key, the
CODE LED will start flashing, at the same time send the first radio control code ("Up"
associated to the Opening direction); now the CODE LED will start flashing rapidly, send
the second code ("Down" associated to the Closing direction) to be stored, the CODE LED
will remain on and programming will be complete. If the second code is not sent within
10 seconds the control unit will exit the programming phase and select the function with
only one key of the radio control.
Programming the "BeFree Series" radio control with 3 Keys.
The control unit can store the whole "BeFree" radio control by programming only the UP
MAIN MENU
—————————————
Led On
Code entered
Courtesy Light
Programmed time
With auto close
Key. The "BeFree" radio control codes are programmed as follows: press the SEL key,
the CODE LED will start flashing, at the same time press the UP key of the desired radio
control; the CODE LED will remain on and programming will be complete.
Deletion:
All the stored devices are deleted as follows: press the SEL key, the CODE LED will start
flashing, then press the SET key for a few seconds, the CODE LED will turn off and the
codes are deleted.
Device already stored or not compatible warning:
The control unit can store up to 120 devices with different codes. If the user attempts to
perform the programming procedure for a device which is already stored in the memory
or which is not compatible, the CODE LED will start flashing rapidly for a few moments to
indicate that this procedure cannot be performed. The unit then returns to the program-
ming phase once again.
Maximum number of devices that can be stored:
The control unit can store up to 120 devices with different codes. If the maximum number
of devices has been reached and a programming process started, the control unit will
indicate that it has failed by flashing all the LEDs except the CODE LED which will remain
lit and steady. After 10 seconds the control unit exits programming mode.
2) LAMP/CORT. : (Selection of the flashing light or the courtesy light)
The control unit has a 230 Vac output, for connection to a flashing light or a courtesy light.
The control unit is supplied by the manufacturer with the Flashing function enabled. If you
wish to enable the flashing beacon function, including during pauses, proceed as follows:
using the SEL key to move to the LAMP/CORT flashing LED then press the SET key, and
the LAMP/CORT flashing LED will switch on steady.
Repeat the operation if you wish to restore the factory setting.
If you wish to enable the courtesy light, repeat the operation described above, pressing
the SEL button twice instead of once (making the LAMP/CORT LED flash rapidly). Repeat
the operation if you wish to restore the factory setting.
3) T. MOT: (Programming the motor operating time max. 4 minutes)
The control unit is supplied by the manufacturer with a working time motor predefined equal
to 30 sec.
If the motor operating time has to be reprogrammed, it must be carried out when the gate
is closed, as follows: use the SEL key to move to the flashing T.MOT LED, then continuously
press the SET key. The frame will start moving up. When you have reached the required height,
release the SET key and at the same time the motor time storage will be completed and the
T. MOT. LED will remain lit and steady. If you want an infinite motor time, use the SEL key to
navigate to the T.MOT LED when flashing and press the SET key for less than 1 second. At the
same time the LED will turn off and the operation will be completed. It is advisable to store a
time that is a few seconds longer after the frame has reached the end.