Alarms
(display version)
When an alarm situation stopping the charge occurs, the display shows one of the information below according failure detected:
Alarm table list here following:
CODE
A01
A02
A03
A05
HIGH TEMPERATURE BATTERY
A07
A08
A11
A14
A16
A20
A21
Notes:
A05:
The charge restarts once the battery temperature reaches a value lower than 45° C.
Connections
OUT
AUX
Input and output cables
INPUT: multiwires cable 3x2.5mm².
OUTPUT (currents up to 25A): Flex cable 6mm² (red wire for the positive pole, black wire for the negative).
OUTPUT (currents up to 50A): Flex cable 10mm² (red wire for the positive pole, black wire for the negative).
Auxiliary inputs and outputs cable
Connector MICRO-FIT 8 outs MA
PIN
Wire colour
1
Black
2
White / Yellow
3
Pink
4
Grey / Pink
5
Violet
6
-
7
Grey
8
Blue / Red
D01596-04
SG6 CAN Bus Interface
<A> <alarm code identified with a 2 digits code>
ALARM TYPE
LOGIC FAILURE #1
CAN BUS KO
WATCHDOG
OVERCURRENT
HIGH TEMPERATURE
TIME OUT
SHORT OUPUT
LOGIC FAILURE #2
EEPROM KO
FLASH CHECKSUM
Description
AUX NC
AUX COM
GND
NPT100
AUX NO
N.C.
Digital Input
PPT100
DESCRIPTION
Trouble on current detection
Trouble on CAN communication
Logic board mis-working
Battery over temperature (>55° C)
Over current
Battery charter high temperature
End of Phase 1 due to timeout
Short circuit ar the output stage
Voltage sag
Problem in EEPROM communication
Microcontroller flash corrupted
Connector MICRO-FIT 8 outs FE
PIN
Wire colour
1
Red
2
Blue
3
Yellow
4
Green
5
White / Green
6
Brown / Green
7
White
8
Brown
English
STOP
YES
NO
YES
Temporary
Temporary
YES
YES
YES
Temporary
YES
YES
IN
Description
CAN POS
CAN NEG
CAN H
CAN L
CAN HT (120Ω già
connesso al CAN H)
CAN L
GND
+12V
11