Load monitor error description
Table 29
Display
ut
Trip for underload
Pre-alarm under-
Put
load
Ot
Trip for overload
POt
Pre-alarm overload
64
Troubleshooting and maintenance
Error
Minimum load alarm level
(underload) has been reached.
Actual load reaches minimum
pre-alarm margin.
Maximum load alarm level (over-
load) has been reached.
Actual load reaches maximum
pre-alarm margin.
Cause
Emotron AB 01-3991-11r2
Corrective Action
1. Check the load condition
of the machine.
2. Check the monitor setting
in [411] to [429].
1. Check the load condition
of the machine.
2. Check the monitor setting
in [411] to [429].
1. Check the load condition
of the machine.
2. Check the monitor setting
in [411] to [429].
1. Check the load condition
of the machine.
2. Check the monitor setting
in [411] to [429].