Important:

For the protection and longevity of your pool equipment, the operating instructions mentioned in this manual must be
followed precisely. The presence of amperometric chlorine regulator, a Redox production controller or a pH regulator
does not remove the need to comply with these instructions strictly, and is not intended to remove the risks of damage
but only to limit them. Despite the proper functioning of a controller or regulator device, other factors are likely to cause
damage, such as:
-
inadequate ventilation in the case of indoor pools (shelter, tarpaulin, cover)
-
lack of maintenance of the analytical probes (calibration, addition of consumables, etc.)
-
excessive or inappropriate extra manual treatments (shock treatment, etc.)
-
failure to follow the instructions for use described in this manual
These factors, individually or in combination, promote the onset of oxidation phenomena on all metal parts of the axles
and blades of electrical automatic covers, telescopic shelters and heat exchangers, and may lead to irreversible damage
(discoloration, etc.) of the pool liner.
Therefore, if the manufacturer's liability were invoked for a fault in the control or regulation device, it would be limited to
the free repair or replacement of the product. Thus, it is strongly recommended to check the chlorine level and water pH
each week with your usual analysis kit.

6/ MAINTENANCE

WINTER LAY-UP PERIOD
1
If laying up the pool for the winter months (emptying it and/or stopping filtration), the following operations
should be performed:
 Remove the pH probe from the pipe and store it in its original protector filled with tap water (or in a glass
of water) in a location where it will not freeze during the winter.
 On the pipe, in place of the probe, insert the supplied plug.
 Rinse the flexible hose of the peristaltic pump with clean water.

CALIBRATING THE PH PROBE

2
R
e
 At the start of each season and after changing the pH probe, the probe must be calibrated to ensure
a
optimal regulation. Proceed as follows:
di
 1/ On the initial installation of the device, the "CA" mode flashes: press the button for 3 seconds.
n
g
of
The display shows a flashing "7.0".
th
e
2/ Dip the pH probe in a pH 7 solution (not supplied).
p
The standard solutions are intended for single use only. Discard them after use.
H
b
y
3/ Press the button
di
After one minute, the display shows "Oh": the probe is calibrated.
o
After 3 seconds, the display returns to the main screen showing the pH value."
d
e
1
4/ To exit the menu and return to the pH value display, press the button
wait 30 seconds.
 If the display shows "Er", the calibration has failed. In that case, press either of the two buttons and
NANO pH – PAPI004092MULTI – FR/EN/DE/ESP/IT/PT – Rev.04.15
again for 3 seconds: the device calibrates the probe
for 3 seconds or simply