Complete The Finished Wall - Kohler K-2971 Guía De Instalación Y Cuidado

Ocultar thumbs Ver también para K-2971:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Thick Wall
Finished Wall
1/2"
(13 mm)
2-1/4" (57 mm)
to 3" (76 mm)
Rough-In Depth
Attachment Hole
Backing Plate
Outer Ring

8. Complete the Finished Wall

CAUTION: Risk of product damage. This valve contains plastic
and rubber components that may become damaged if soldering heat
is applied directly to the valve body.
CAUTION: Risk of damage to the K-2971-KS valve assembly.
When using the K-2971-KS HiFlow Valve in a fiberglass or acrylic
installation, use the Thin Wall Installation Kit (88526).
NOTE: Thick wall installations are typically tile, plaster, marble, or
similar materials. Thin wall installations are typically fiberglass and
acrylic.
NOTE: Do not adjust the maximum water temperature at this time.
Thick Wall Installation
Provide a 5-9/16" (141 mm) diameter hole in the wall material.
The flat front surface of the plaster guard must be flush with the
finished wall.
Complete the finished wall.
Do not remove the plaster guard until instructed.
Kohler Co.
Backing Plate
1/2"
(13 mm)
Ø 5-9/16"
(141 mm)
Plaster
Guard
Dome
Plaster
Guard
11
Thin Wall
Ø 4"
(102 mm)
2-1/4" (57 mm)
Rough-In Depth
Valve Stem
Dome
1205550-2-C

Publicidad

Tabla de contenido
loading