S.A.S. au capital de 5 000 000 € - Z.I. Les Giranaux - BP71 - 70103 ARC-LÈS-GRAY CEDEX - FRANCE - RCS VESOUL B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090
These instructions apply to all T3.5 EHz DC drive, the different versions of which are available in the current catalogue.
Field of application: T3.5 EHz DC drive are designed to all types of roller shutters. The installer, who must be a motorisation and home
automation professional, must ensure that the drive product is installed in accordance with the standards in force in the country in which
it is installed such as EN 13659 relating to roller shutters.
Liability: Before installing and using the drive, please read operating and installation guide carefully. Please read these
instructions carefully before installing and using the drive. In addition to following the instructions given in this guide, the instructions
detailed in the attached Safety instructions document must also be observed. The drive must be installed by a motorisation and home
automation professional, according to instructions from SIMU and the regulations applicable in the country in which it is commissioned.
It is prohibited to use the drive outside the field of application described above. Such use, and any failure to comply with the instructions
given in this guide and in the attached Safety instructions document, absolves SIMU of any liability and invalidates the warranty. The
installer must inform its customers of the operating and maintenance conditions for the drive and must provide them with the instructions
for use and maintenance, and the attached Safety instructions document, after installing the drive. Any After-Sales Service operation
on the drive must be performed by a motorisation and home automation professional. If in doubt when installing the drive, or to obtain
additional information, contact a SIMU adviser or go to the website www.simu.com.
i
AUTOSUN 2 SYSTEM PRESENTATION
The T 3.5 EHz DC motor is part of the Autosun 2 system which references are available in the current catalogue.
It is a powered system working with solar energy. The electrical energy supplied by the solar panel is stored
inside the battery of the system. This system was developed to run into the following countries: France, Germany,
England, Belgium, Netherlands, Czech Republic, Poland, Ireland, Spain, Portugal, Italy, Greece, Switzerland,
Luxembourg, Denmark, Austria, Hungary, USA (excluding Alaska), Australia and Turkey. For other countries,
please contact us.
4
+
Réf. 9019722
Réf. 9020638
i
• The weight of roller shutter must comply with the charts determined for the motors. Maximum shutter heights
are: 1600 mm for 3Nm motors, 2400 mm for 6Nm motors and 2700 mm for 10Nm motors.
• These consign are based on average annual data and for a roller shutter used for 2 cycles/day (1 cycle = 1 up
and 1 down movement). Caution 1 cycle maximum for the 10 Nm motor when North orientation (or South
orientation for Australia only). In exceptional years, use the battery charger to recharge the Autosun 2 's battery.
• The solar panel should always be placed on the shutter housing so as to be as exposed as possible to the sun's
rays.
2
T3.5 EHz DC
1
2
5
+
Réf. 9019683
6
(12VDC)
Autosun 2 system components:
1- 12V motor T3.5 EHz DC, 3, 6 or 10 Nm.
2- SOLAR PANEL 12V: 3,2W / Voc: 21V / Isc : 196 mA.
3- Battery NiMh 12V: 2.2Ah
In option:
4- Battery charger ref. 9020638. Allows rapid recharging of the
3
battery for the Autosun 2 system.
5- Solar Panel bracket ref.: 9019683
6- Extension cable 5m ref.: 9019722
5136882A
EN- ORIGINAL INSTRUCTIONS
i
-20°C / +60°C
EN