TROUBLESHOOTING - dryWIRE® OVENS
OVEN FAILS TO OPERATE - NO HEAT
1. If oven indicator light will not illuminate, check power sup-
ply.
2. Check indicator light for continuity (see Repair Parts draw-
ing for access details). If defective, replace indicator light.
3. Check thermostat on front door. If indicator light illumi-
nates, power is being supplied through thermostat to dual
heating elements. Turn knob from low to high setting and
return. A "snap" should be heard at low temperature end
and indicator light should turn off and on with each "snap"
cycle. If "snap" is not heard and indicator light fails to oper-
ate, replace entire thermostat. (See Repair Parts Sheet)
4. If thermostat operates satisfactorily, check continuity of
heating elements at bottom of oven.
removable lower panels.) Failure of one element will pre-
vent oven operation on 480 volts. If operating on 240 volts
failure of one element will cause slow heating. Remove
oven from power source. Replace BOTH elements. Pairing
of one new element with an old element may cause rapid
failure of old element.
OVEN OPERATES - OVERHEATS
1. Check thermostat operation as in number 3 (Oven Fails
To Operate - No Heat) and number 2 (Oven Operates -
Temperature Setting Off).
OVEN OPERATES - TEMPERATURE SETTING "OFF"
1. Check thermostat operation as in number 3 (Oven Fails
To Operate - No Heat) above.
(Access through
2. If thermostat operates satisfactorily, recalibrate per
attached thermostat calibration adjusting sheet.