Before you install the appliance, fit it with the
applicable hob from the table.
Type
ZEE 6041
ZEV 6040
ZEV 6041
ZEV 6046
BUILDING IN
SECURING THE APPLIANCE TO THE
CABINET
ELECTRICAL INSTALLATION
The manufacturer is not responsible if
you do not follow the safety
precautions from the Safety chapters.
This appliance is supplied without a main plug and
a main cable.
CABLE
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05
V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total power
on the rating plate.
18
Maximum power
7000 W
6000 W
6400 W
7600 W
600
9
3
A
B
ELECTRICAL CONNECTION WITH THE HOB
The hob connection socket is at the top of the oven
cabinet. The hob has connection leads for the
cooking zones and the ground cable. The leads
have plug-in connectors. To connect the hob to the
oven, plug the connectors into the correct oven
sockets. The design of the plugs and sockets
prevents incorrect connections.
540
558
min. 550
20
19
min. 560
570
CONNECTING THE TERMINAL BOARD
The appliance has a six-pole terminal board. The
jumpers (bridges) are set for operation on a 400 V
three-phase with a neutral wire.
1
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange the
jumpers on the terminal board (refer to the
connection diagram below). Connect the ground
cable to the terminal. After you connect the supply
cable to the terminal board, attach it with a junction
clamp.
21
114
589
598
594
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
2
3
4
5