Yamato HCM 650 Manual Del Usuario página 32

Ocultar thumbs Ver también para HCM 650:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Problem
Possible Causes
Tool will not
1.Cord not connected.
start.
2.No power at outlet.
.
3.Internal damage or wear.
Tool
Extension cord too long or wire
operates
size too small.
slowly.
Excessive
1.Belt (if equipped) too loose
noise or
(slipping) or too tight (bearing
rattling.
damage).
2.Internal damage or wear.
Overheating/
1.Running at 100% load for
Overloading.
extended time.
2.
Blocked
vents.
3. Motor being strained by long
or small diameter extension
cord.
Follow all safety precautions whenever diagnosing or
servicing the tool.
Disconnect power supply before service.
Troubleshooting
Likely Solutions
1.Check that cord is plugged in.
2. Check power at outlet. If outlet is
unpowered, turn off tool and check circuit
breaker. If breaker is tripped, make sure
circuit has the correct capacity for the tool
and circuit has no other loads.
3. Have technician service tool.
Eliminate use of extension cord. If an
extension
shorter/heavier
Extension Cords in GROUNDING section.
1. Properly tension belt.
2. Have technician service tool.
1.Allow for lighter no-load intervals.
2. Wear ANSI-approved safety goggles
motor
housing
and NIOSH-
approved
blowing dust
out of motor using compressed air.
3.Eliminate use of extension cord. If an
extension cord is needed, use one with
the proper diameter for its length and
load.
GROUNDING section.
cord
is
needed,
gauge
dust
mask/respirator
See
Extension
use
cord.
See
while
Cords
in

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

98623

Tabla de contenido