Every Six Months; Cleaning Cautions; Battery Removal - Remington HC5302 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
ENGLISH
To clean the unit, wipe with a damp cloth and dry immediately.
Place a few drops of cutter or sewing machine oil onto the blades. Wipe off
excess oil.

, EVERY SIX MONTHS

Remove the 2 screws retaining the fixed blade with a screwdriver.
Remove the blade set.
Brush out hairs from between the blades with a soft cleaning brush. Do not
remove the lubricating grease from the blades. It is not necessary to remove
the small moving blade from the unit.
If the moving blade has been removed this can be re-fitted by slotting the
moving blade holder over the pin in the centre of the interior product head.
The groove on the moving blade just below the teeth should rest on the
plastic pressure arm which rides inside the groove. The fixed blade should
be assembled with the bevelled edge of the 2 screw holes facing outward
and fixed with screws.
Note that if the blades are not correctly aligned then cutting efficiency will
be impaired.

, CLEANING CAUTIONS

Cleaning should only be done with a soft brush, such as the brush supplied
with the product.
Do not rinse under water.
Do not use harsh or corrosive cleaners on the units or their blades.
Ensure the appliance is switched off and unplugged from the main outlet
before cleaning

BATTERY REMOVAL

The appliance must be disconnected from the supply mains when removing
the battery.
Turn the trimmer on and discharge all remaining power.
Remove the comb attachment.
Remove the blade.
Pry the decorative panel off the top housing to expose the internals and
printed circuit board.
Remove the assembly of battery and printed circuit board.
Disconnect the battery from the circuit board.
The battery is to be disposed of safely.
7

Publicidad

Tabla de contenido
loading

Tabla de contenido