VCT Ozone Generator
Use and maintenance manual
7.3
Preliminary operations be-
fore ozone procedure
1.
Identify the vehicle/rooms cabin/interior with a label
of adequate size to forbid entry and sitting in the
vehicle/rooms.
2.
Do not switch on any appliances/equipment/lights/
gas/fire etc. in the vehicle/room.
3.
Do not switch on the A/C system of the vehicle/
rooms cabin/interior.
4.
Close every vehicle/room doors/ windows.
7.4

Power supply

Connection to vehicle's 12VDC cigarette
lighter socket.
Connect the power cable to the vehicle's ciga-
rette lighter socket after checking voltage and
power conform with the ratings on the equip-
ment's nameplate.
Connection to the mains socket
If the 110-230 VAC power accessory (optional) is
used, make sure the mains socket is grounded.
7.5
Setting and start of O3
ozone generation treat-
ment
1.
In case you want to use a program other than the
standard one P1, press START until the desired
program is selected (allows selecting the program,
sliding the red Led over the desired program in se-
quence P1 – P2 – P3).
2.
Press START and hold for 2 seconds to start the
procedure. When the button is released, a 5 sec-
ond countdown starts, marked by 5 acoustic
signals, "beeps" (after the countdown, the Ozone
generation procedure will start).
3.
Exit immediately from the vehicle/room and close
the door and wait for the treatment to be complet-
ed; also make sure doors are completely closed
and no Ozone is being released.
4.
After the countdown, the equipment will start the
ozone generation procedure for the duration set in
the selected program.
In this moment the equipment starts to generate
O3 ozone.
5.
At the end of the procedure, the equipment stops
generating Ozone, an acoustic signal is made and
the "Status Led" turns steady green.
Now open all the doors of the vehicle from the out-
6.
side to ensure ventilation and air change. Wait 20
minutes at least before entering (unless otherwise
indicated in case of use of the equipment via the
"O3 EASY" App). The operator shall wear an active
carbon protective mask when approaching.
7.
For rooms - finished the ozone treatment,
wait 5 hours at least before entering the room
to open windows and exit immediately and
wait again 5 hours (unless otherwise indicat-
27
ed in case of use of the equipment via the "O3
EASY" App). When you enter, do not forget
to wear the protective mask. (active carbon
protective mask).
8.
Provide for proper room's interior ventilation
including in the floor area (ozone vapors are
heavier than air). If necessary, change air in-
side the room also with air extractor system
to achieve the removal of ozone and an ade-
quate air change with fresh air.
7.6
Sanitation Report
Sanitation report: to be manually filled in is avail-
able at the following links:
www.sanification.org