Principle
Movement triggers light. For your convenience and safety. The integrated pyroelectric infrared detector
senses the invisible heat radiated from moving objects (people, animals, etc.). The heat detected in this way
is converted electronically into a signal that activates the light connected. Heat radiation is not detected
through obstacles, such as walls or glass, and will therefore not activate the light.
Safety warnings
■ During installation, the electrical wiring being connected must be dead. Therefore, switch off the power
■ Installing this light involves work on the mains voltage supply. This work must therefore be carried out
■ Only use genuine replacement parts
■ Do not dismantle the light yourself. It must only be repaired by a specialist workshop.
Installation
L = live conductor (usually black or brown), N = neutral conductor (usually blue)
PE = any protective earth conductor (green/yellow)
Attention: Insulate any PE protective earth conductor in the power supply cable with adhesive tape.
a Connection, concealed wiring a Connection with surface wiring using spacers
Attention: A mains switch for switching the light ON and OFF can of course be installed in the mains lead.
Important: Reversing the connections may result in damage to the unit. Please note that the light must be
protected by a 10 A circuit breaker.
Function
Twilight setting (factory setting: daylight operation at 2000 lux):
The sensor's response threshold can be infinitely varied from 2 – 2000 lux.
Control dial set to
Control dial set to
To adjust the detection zone in daylight, the control dial must be set to
Time setting (factory setting: 8 sec.):
Light ON time can be adjusted continuously from 8 sec. to 35 min.
Control dial set to – = shortest time (8 sec.).
Control dial set to + = longest time (35 min.)
When setting the detection zone, it is recommended to select the shortest time.
Adjusting the detection zone
a using adhesive shrouds, for example, to mask out paths or neighbouring premises
a reach can be adjusted as required to between 2 and 10 m by tilting the lens 90°.
10
Troubleshooting
No power / Fuse faulty, not switched ON ➩ new fuse, turn power switch ON, check lead with voltage
tester. Will not switch ON / Surroundings still too bright ➩ wait until response threshold is reached or
adjust setting / Bulb faulty ➩ change bulb / Power switch OFF ➩ switch ON / Detection zone not properly
targeted ➩ readjust. Will not switch OFF / Surroundings not yet bright enough ➩ wait until response
threshold is reached or adjust setting / Permanent movement in the detection zone ➩ adjust detection
zone. Switches ON when unwanted / Detecting cars on the road, for example ➩ change detection zone,
tilt sensor down. Reach changing / Differing ambient temperatures ➩ at low temperatures, shorten reach
by tilting sensor down; at high temperatures, tilt sensor up.
Declaration of conformity
This product complies with Directive 2006/95/EC on low-voltage appliances and EMC Directive 2004/108/EC.
Functional warranty
This STEINEL product has been manufactured with utmost care, tested for proper operation and safety in
line with applicable regulations and then subjected to random sample inspection. STEINEL guarantees that
it is in perfect condition and proper working order. The warranty period is 36 months and starts on the date
of sale to the consumer. We will remedy defects caused by material flaws or manufacturing faults. The
warranty will be met by repair or replacement of defective parts at our own discretion. The warranty shall
not cover damage to wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other objects is excluded. Claims under the warranty shall only be accepted if the
product is sent fully assembled and well packed complete with a brief description of the fault, a receipt or
invoice (date of purchase and dealer's stamp) to the appropriate Service Centre.
Service:
Our Customer Service Department will repair faults not covered by warranty or after the warranty period.
Please send the product well packed to your nearest Service Centre.
2
ENGLISH
first and use a voltage tester to check that the power supply is disconnected.
by a specialist in accordance with the applicable national wiring regulations and electrical operating
conditions. ( D - VDE 0100, A -ÖVE-ÖNORM E8001-1,
-SEV 1000)
a
a
–
1
7
4
5
a
8
= daylight operation at approx. 2000 lux.
= night-time operation at approx. 2 lux.
9
(Fault / Cause ➩ Remedy)
3
GB
(daylight operation).
Tip!
5 min.
min.