3. The power supply cable sections can withstand the load specified on the rating plate.
To connect the hob to the mains power supply, do not use adapters, reducers, or branching
devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its
temperature will not exceed 75˚C at any point.
Check with an electrician whether the domestic wiring system is suitable without alterations.
Any alterations must only be made by a qualified electrician.
If the total number of heating unit of the appliance you choose is not less than 4, the appliance
can be connected directly to the mains by single-phase electric connection, as shown below.
If the cable is damaged or to be replaced, the operation must be carried out the by after-sale
agent with dedicated tools to avoid any accidents.
If the appliance is being connected directly to the mains an omnipolar circuit-breaker must be
installed with a minimum opening of 3mm between contacts.
The installer must ensure that the correct electrical connection has been made and that it is
compliant with safety regulations.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by authorised technicians only.
The bottom surface and the power cord of the hob are not accessible after installation.