L – Longopac
Close the bag using the supplied cable ties when you believe that it has been filled to a suitable level. Another cable tie is used a
little further up. This forms the bottom of the next bag. The filled bag is then cut off, and the machine is ready to be used again.
Changing the bag magazine
1.
Rotate the holder to the position in which it can be pulled down.
2.
Insert a bag magazine into the holder and refit it.
3.
Cut the four tapes that hold the bag magazine together and pull the inner end of the bag upwards over the rubber strip. Then
secure the bag with the strap. Pull the outer end over the holder, and tie a cable tie in place as a bottom closure.

Service/Maintenance

Cleaning
The machine must be switched off and unplugged before cleaning and maintenance.

Filter replacement

The fine filter must be replaced at least once a year. Only original filters may be used. HEPA filters must be replaced after
300 hours.
WARNING
Filter replacement may only be performed by trained personnel. Use a protective mask and suitable
equipment.
Release and lift off the upper part for free access to the filter. Lift the filter straight up. If appropriate, fit a plastic bag over the
cyclone to prevent the dust in the filter from spreading. Check the gasket when replacing the filter. A worn gasket can allow
hazardous dust to escape. Never use old gaskets or non-OEM parts. Place used filters in a plastic bag and seal the bag. See
instructions below.
1
24
2
3
DC Tromb Turbo, 99049-B
4