Service/Maintenance

Cleaning
The machine must be switched off and unplugged before cleaning and maintenance.

Filter replacement

The fine filter must be replaced at least once a year. Only original filters may be used. HEPA filters must be replaced after
300 hours.
WARNING
Filter replacement may only be performed by trained personnel. Use a protective mask and suitable
equipment.
Release and lift off the upper part for free access to the filter. Lift the filter straight up. If appropriate, fit a plastic bag over the
cyclone to prevent the dust in the filter from spreading. Check the gasket when replacing the filter. A worn gasket can allow
hazardous dust to escape. Never use old gaskets or non-OEM parts. Place used filters in a plastic bag and seal the bag. See
instructions below.
1
Motor
The typical service life of a fan motor's original brushes is 600-700 hours. The brush can be replaced. The service life of the
second brush set is approx. 400 hours, while that of the third set is approx. 300 hours. After this time, the motor is considered
worn out and should be replaced.
Overheating
If the machine risks becoming overheated (for example by heavy throttling), the temperature monitor trips and the machine stops.
It is then important that the operator presses the power switch to the OFF position, pulls the cord out of the socket and waits 3-5
minutes for the machine to cool down. Then the temperature monitor is reset by pressing the RESET button. Reassemble the
power cord and restart the machine by pressing the power switch to the ON position. in DC Tromb 600 there are 2 thermal guards
and thus there are also 2 RESET buttons (see picture).