Troubleshooting (cont.)
Symptoms
Probable
Causes
D. There is
E. The
F.
G. Supply
H. Incorrect
I.
J.
K. Sensor
Kohler Co.
Recommended Action
D. Remove the cover and check
water
for corrosion on the
leakage on
connections between the
electrical
battery to solenoid and the
components
battery holder to the sensor. If
or
possible, clean the terminals. If
connectors.
unable to repair the connection,
order a new sensor assembly,
battery holder, or solenoid
assembly, as required. Inspect
the gasket between the valve
body and spout hose for cuts,
debris, etc. If the gasket is
damaged, order a new gasket.
The origin of the leak must be
investigated and repaired.
E. Remove the cover and replace
battery life
the battery. The faucet requires
has
a standard 2CR5 6 V lithium
expired.
battery. This item is not
available from Kohler Co., but
can be purchased at retail
stores.
Sensor
F.
Wipe the sensor eyes with a
eyes are
damp soft cloth. Wipe dry with
dirty.
a dry soft cloth.
G. Verify that the water supply is
pressure is
turned on and that pressure is
low.
at least 20 psi (137 kPa).
H. Verify that the faucet is
installation.
mounted flat to the deck
surface and that the sensor eyes
are aligned to the user area.
Refer to the "Service the Filters"
The filters
I.
are
section of the Homeowners
plugged.
Guide.
The
J.
Remove the aerator and clean.
aerator is
For calcium/mineral deposits,
plugged.
soak the plastic insert in a 50:50
mix of water and vinegar. Soak
only the plastic insert.
K. Replace the sensor assembly.
eyes are
scratched.